The level shown is the LAST level the jug reported, not the water in it now. The jug reports a new level around pours and fills and holds its last value between them, so a jug that has been emptied or lifted can go on reporting its old reading while the radio stays healthy. Where the level has not moved for 2 hours or more the page says so and stops calling it live. The reading also has a floor: the lowest level ever reported by this jug is 69 ml, and zero has never been reported, so a low number is a prompt to look and not proof the jug is empty.The levels beside each event are the ones the jug actually reported at the time. They are not worked back from the current reading: a jug emptied out of sight of the poller never reports the drop, so that arithmetic ran past zero and printed volumes no jug can hold. Where the jug was not reading just before an event, the page says the level was not measured instead of computing one. Refills are level rises of 100 ml or more between samples, detected by the server poller.The level after a fill is always measured. The amount added is not, so each fill states its basis: measured, a minimum when the jug was offline and did not read the level before, or assumed poured away when the water was more than 24 hours old.A level fall of 50 ml or more with no drink row within 30 minutes shows as "no drink log". It can be a drink, a pour-out or a spill. It is not added to Drunk today.Source: Smart Hydration Abacus API, device , firmware .